Audix Systems,
Station Road,
Wenden,
Saffron Walden,
Essex,
CB11 4LG.
Telephone: +44(0)1799 540888
Facsimile: +44(0)1799 541618
~
Page 14 of 25
PA-VA Application Guide
Small zones which do not require dual speaker lines (such as Lifts) will use a single 60W
PowerBloc driving a single speaker line (figure ?a)
Larger zones requiring dual speaker lines but with less than 120W total power required will
have dual redundant speaker lines each driven by one 60W PowerBloc amplifier (figure ?b).
Therefore, if one PowerBloc fails the sound coverage in the affected zones will reduce but will
not be lost.
Large zones requiring dual speaker lines but with more than 120W total power required will
have dual redundant speaker lines each driven by multiples of 60W PowerBloc amplifiers in
parallel (figure ?c). Therefore, if one PowerBloc fails the power into one speaker circuit will be
reduced (but not lost) and the sound coverage in the affected zones will be slightly reduce.
Using the latest MOSFET circuit techniques results in an efficient and extremely reliable
power amplifier. The amplifiers are protected from short circuit speaker lines by current
limiting on the output stage. Also the amplifiers are protected from persistently being over-
driven by a thermal cut-out which is triggered at 85 °C this reduces the amplifier input drive to
reduce the transistor load.
The output power of existing units can be increased at any time by the addition of more
PowerBloc output modules (subject to available space in the mainframe).
The use of parallel reliable amplifiers to drive each zone negates the need for hot or cold
standby spare amplifiers as the system will remain available under the failure of one
PowerBloc.
For more information on amplifiers please refer to User Manual Ref 21015
The following standard amplifier configurations can be utilised;
Monitored Non-monitored
1 X 120W POWER AMPLIFIER 570.001.024 570.001.010
2 X 120W POWER AMPLIFIER
570.001.013 570.001.020
1 X 120W + 1 X 60W POWER AMPLIFIERS
570.001.022 570.001.018
1 X 120W + 2 X 60W POWER AMPLIFIERS
570.001.023 570.001.019
1 X 180W POWER AMPLIFIER
570.001.014 570.001.011
1 X 180W + 1 X 60W POWER AMPLIFIERS
570.001.025 570.001.012
1 X 240W POWER AMPLIFIER
570.001.001 570.001.003
1 X 60W POWER AMPLIFIER
570.001.026 570.001.009
2 X 60W POWER AMPLIFIER
570.001.015 570.001.021
3 X 60W POWER AMPLIFIER
570.001.027 570.001.017
4 X 60W POWER AMPLIFIER
570.001.002 570.001.004
6 Fault Monitoring
Audix offers the opportunity to monitor the audio path of public address and voice alarm